Products

Contact Us

You are here:Home >> Products >> Indoor Fiber Optic Cable... >> Drop Cable

Drop Cable

Pre-Terminated Round Drop Cable

Pre-terminated cable offers a robust and sealed connection solution for fiber to the home (FTTH), through a fast and precise connection system, reducing installation time, technical errors, and maintenance. In addition, it guarantees high reliability and durability of the network.

This product is a G657 optical single mode with a reinforced SC/APC connector at one end, and the other end is open, the connector ferrule is zirconium. Cable Construction: G657A1/G657A2 5mm outer cable.

A side connector: Reinforced SC/APC connector per IEC 61754-4

B side connector: open

Cable: 5mm, HDPE, black/gray

    Structure Drawing 

    1.900μm buffer

    2.PBT tube

    3.Water-blocking fiberglass and aramid yarn fiber buffers

    4.Ripcord

    5.LSZH Jacket


    1.900μm buffer

    2.Inner Sheath

    3.Water-blocking fiberglass and aramid yarn fiber buffers

    4.Strength member

    5.Ripcord

    6.Outer Sheath

    7.Blue Color Line

    Connector Details

    Model: Type E

    Colour: Black

    Material: PC+ABS

    Connector: SC/APC

    Applicable cable: 5mm drop cable

     

    Characteristics 

    Modular design, easy to expand
    It can work and be installed outside
    Protection degree: IP68
    RL: ≥55dB

    Optical Specifications 

    Parameter

    Value

    Connector Type

    E Type

    Connector Insertion Loss (dB)

    IL: ≤0.3dB

    Max. 0.3dB + 0.4dB/km * L(km) @ 1310nm

    Max. 0.3dB + 0.35dB/km * L(km) @ 1550nm

    according to IEC 61300-3-4 Method B

    IL: ≤0.3dB

    Connector Return Loss (dB)

    RL: ≥55dB

    Min. 60dB @ 1310&1550nm

    According to IEC 61300-3-6

    Cable length (m)

    50, 100, 150, 200, 250, etc

    Degree of Protection

    IP 68

     

    Cable Assembly

    Insertion Loss: Max. 0.3dB + 0.35dB/km * L(km) @ 1310nm

    Max. 0.3dB + 0.21dB/km * L(km) @ 1550nm

    According to IEC 61300-3-4 Method B

    Return Loss: Min. 60 dB @ 1310&1550nm

    According to IEC 61300-3-6

     

    Mechanical Specifications 

    Item

    Testing method

    Requirement

    Tensile Strength

    IEC 60794-1-E1

    (1000N/1h)

    Fiber Elongation ≤0.40%

    Residual Elongation ≤ 0.05%

    Attenuation Change≤ 0.1 dB @1550nm

    Flattening

    IEC 60794-1-E3

    (1000 N/100mm in 15 minutes)

    Attenuation Change ≤ 0.1 dB @1550nm

    Impact

    IEC 60794-1-2-E4

    (5N.m impact and D=300mm)

    Attenuation Change ≤ 0.1 dB @1550nm

    Torsion

    IEC 60794-1-2-E7

    (25N load and 10 cycles)

    Attenuation change ≤ 0.1 dB @1550nm

    Curvature

    IEC 60794-1-2-E6

    (D=100mm and 55N load, 25 cycles)

    Attenuation change ≤ 0.1 dB @1550nm

    Temperature Range

    IEC 60794-1-2-F1

    (-15°C ~ + 65°C)

    Attenuation change ≤ 0.2 dB @1550nm

    Water Penetration

    IEC 60794-1-2-F5A

    (3m in length, 1m in height, 24 hrs)

    End water leak

    Sheath Shrinkage

    EIA-RS-455-86 (85°C, 4HRS)

    ≤ 5.0%

    RoHs (2011/65/EU

    Complies

     

    Please submit your basic information, we will contact you as soon as possible!

    *

    *

    *

    *