Structure Drawing
1.900μm buffer
2.PBT tube
3.Water-blocking fiberglass and aramid yarn fiber buffers
4.Ripcord
5.LSZH Jacket
1.900μm buffer
2.Inner Sheath
3.Water-blocking fiberglass and aramid yarn fiber buffers
4.Strength member
5.Ripcord
6.Outer Sheath
7.Blue Color Line
Connector Details
Model: Type E
Colour: Black
Material: PC+ABS
Connector: SC/APC
Applicable cable: 5mm drop cable
Characteristics
Modular design, easy to expand
It can work and be installed outside
Protection degree: IP68
RL: ≥55dB
Optical Specifications
Parameter |
Value |
Connector Type |
E Type |
Connector Insertion Loss (dB) |
IL: ≤0.3dB Max. 0.3dB + 0.4dB/km * L(km) @ 1310nm Max. 0.3dB + 0.35dB/km * L(km) @ 1550nm according to IEC 61300-3-4 Method B IL: ≤0.3dB |
Connector Return Loss (dB) |
RL: ≥55dB Min. 60dB @ 1310&1550nm According to IEC 61300-3-6 |
Cable length (m) |
50, 100, 150, 200, 250, etc |
Degree of Protection |
IP 68 |
Cable Assembly
Insertion Loss: Max. 0.3dB + 0.35dB/km * L(km) @ 1310nm
Max. 0.3dB + 0.21dB/km * L(km) @ 1550nm
According to IEC 61300-3-4 Method B
Return Loss: Min. 60 dB @ 1310&1550nm
According to IEC 61300-3-6
Mechanical Specifications
Item |
Testing method |
Requirement |
Tensile Strength |
IEC 60794-1-E1 (1000N/1h) |
Fiber Elongation ≤0.40% Residual Elongation ≤ 0.05% Attenuation Change≤ 0.1 dB @1550nm |
Flattening |
IEC 60794-1-E3 (1000 N/100mm in 15 minutes) |
Attenuation Change ≤ 0.1 dB @1550nm |
Impact |
IEC 60794-1-2-E4 (5N.m impact and D=300mm) |
Attenuation Change ≤ 0.1 dB @1550nm |
Torsion |
IEC 60794-1-2-E7 (25N load and 10 cycles) |
Attenuation change ≤ 0.1 dB @1550nm |
Curvature |
IEC 60794-1-2-E6 (D=100mm and 55N load, 25 cycles) |
Attenuation change ≤ 0.1 dB @1550nm |
Temperature Range |
IEC 60794-1-2-F1 (-15°C ~ + 65°C) |
Attenuation change ≤ 0.2 dB @1550nm |
Water Penetration |
IEC 60794-1-2-F5A (3m in length, 1m in height, 24 hrs) |
End water leak |
Sheath Shrinkage |
EIA-RS-455-86 (85°C, 4HRS) |
≤ 5.0% |
RoHs (2011/65/EU |
Complies |
|